    Digital Oxygen Index Analyzer

    Ask Lasest Price
    Brand Name : BAXIT
    Model Number : BXT-JF
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, Western Union
    Supply Ability : 10Set per day
    Delivery Time : 5-8 days
    • Product Details
    • Company Profile

    Digital Oxygen Index Analyzer

    Digital Oxygen Index Analyzer


    Product Name: Digital Oxygen Index Tester
    TIPS: Digital Oxygen Index Tester with temperature controller to control temperature, the other parameters are consistent with JF-3 type digital oximetry index analyzer.


    First, the scope of application:
    Suitable for the determination of the burning properties of plastics, rubber, fiber, foam, film and film and textile materials


    Second, the main technical parameters:
    1. Using imported oxygen sensor, the digital display shows the oxygen concentration without calculation, the accuracy is higher and more accurate, the range is 0-100%
    2. With temperature controller to control temperature, control range: 23 ° C ± 2 ° C
    3. Digital resolution: ±0.1%
    4. Measurement accuracy: 0.4
    5. Flow adjustment range: 0-10L/min (60-600L/h)
    6. Response time: <5S
    7. Combustion tube: inner diameter ≥75mm high 400mm
    8. Gas flow rate in the combustion cylinder: 40mm ± 2mm / s
    9. Pressure gauge accuracy 2.5, resolution: 0.01MPa
    10. Flowmeter: 1-15L/min (60-900L/H) adjustable, test environment: ambient temperature: room temperature ~ 40 °C;, relative humidity: ≤ 70%;
    11. Input pressure: 0.2-0.3MPa
    12. Working pressure: nitrogen 0.1-0.15Mpa Oxygen 0.1-0.15Mpa Oxygen/nitrogen mixed gas inlet: including pressure regulator valve, flow regulating valve, gas filter and mixing chamber.
    13. Sample holders can be used for soft and rigid plastics, textiles, fire doors, etc.
    14. Propane (butane) ignition system, flame length 5mm-60mm can be adjusted freely
    15. Gas: industrial nitrogen, oxygen, purity >99%; (user-supplied).
    16. Power requirements: AC220 (+10%) V, 50HZ
    17. Maximum operating power: 50W
    18. Ignition: There is a metal tube with a nozzle with an inner diameter of Φ2±1mm at the end. It can be inserted into the combustion tube to ignite the sample. The flame length is 16±4mm, and the size can be adjusted.
    19. Self-supporting material sample holder: can be fixed at the axial position of the combustion tube and can clamp the sample vertically
    20. Non-self-supporting material sample holder: can fix two vertical sides of the sample to the frame at the same time


    Third, the chassis and part of the structure:
    1. Control box: It is processed by CNC machine tool, electrostatic spraying, beautiful, anti-rust and anti-corrosion. Control part and test part are controlled separately
    2. Combustion tube: high temperature resistant high quality quartz glass tube (inner diameter ¢75mm, length 300mm) Outlet diameter: φ40mm
    4. Mixer: Mix the oxygen and nitrogen evenly with a glass bead filler. (Bead φ4.5mm filling height 95mm, one bag)
    5. Specimen fixture: self-supporting clamp, and can clamp the specimen vertically; (optional non-self-supporting style bracket), two sets of clamps meet different test requirements; style clamp plug-in type, placement style Easier with style clips
    7. The standard is equipped with a glass tube to prevent accidental damage and meet the requirements of uninterrupted test; the diameter of the end of the long rod igniter is ±2±1mm, and the length of the igniter flame (5-50)mm can be adjusted freely.


    Forth, Design standard: GB/T 2406.2-2009 GB/T 2406.1-2008
    Compliance with standards: ASTM D 2863, ISO 4589-2, NES 714 GB/T 5454 GB/T 10707 GB/T 8924-2005 GB/T 16581-1996 NB/SH/T 0815-2010 TB/T 2919-1998 IEC 61144 -1992 ISO 15705-2002 ISO 4589-2-1996


    Fifth, packing list:
    Host 1
    2. Burning tube 1 set
    3. Ignition 1
    4. Power cord 1
    5. Spare glass tube 1
    6. Glass beads 1 bag (into the combustion column)
    7. Nylon tube Ф 4 1.2 m (connecting the combustion column to the main unit)
    8. Sealing ring
    9. Pointed sample holder 1 set
    10. One metal mesh (into the combustion column)
    11. Plastic air outlet plate 1
    12. Rubber hose 2
    13. M10×1 inner joint screw 1 (within the combustion column)
    14. M10×1 joint nut 1 piece (connected to the main unit)
    15. Instructions 1 copy
    16. Non-self-supporting sample holder 1 set (optional)